 Thermal Monitor and Fan Speed (RPM) Controller ADM1033
FEATURES
1 local and 1 remote temperature channel 1.5C accuracy on local and remote channels Automatic series resistance cancellation on remote Temperature channels > 1 k Fast (up to 64 measurements per second) SMBus 2.0, 1.1, and 1.0 compliant SMBus address input/LOCATION input to UDID Programmable over-/undertemperature limits Programmable fault queue SMBusALERT output Fail-safe overtemperature comparator output Fan speed (RPM) controller Look-up table for temperature-to-fan-speed control Linear and discrete options for look-up table FAN_FAULT output THERM input, used to time PROCHOT assertions REF input, used as reference for THERM (PROCHOT) 3 V to 5.5 V supply Small 16-lead QSOP package
APPLICATIONS
Desktop and notebook PCs Embedded systems Telecommunications equipment LCD projectors
FUNCTIONAL BLOCK DIAGRAM
VCC
6
ADM1033
SMBUS ADDRESS
16 15
MANUAL FAN SPEED CONTROL REGISTERS
SERIAL BUS INTERFACE ADDRESS POINTER REGISTER ALERT STATUS REGISTER THERM MASK REGISTERS FAULT QUEUE
SCL SDA
8 3 14 7
FAN_FAULT ALERT Comp SMBusALERT THERM
TEMPERATURE-TOFAN-SPEED LOOK-UP TABLE
DRIVE 1
FAN SPEED CONTROLLER
FAN RESPONSE
LIMIT COMPARATOR
TACH 2 NC 4
TACH SIGNAL CONDITIONING
FAN SPEED COUNTER
VALUE AND LIMIT REGISTERS
THERM PERCENT TIMER
REF 8 LOCATION 13 D-
9
FAULT QUEUE HYSTERESIS REGISTERS ANALOG MULTIPLEXER SRC BLOCK BAND GAP REFERENCE BAND GAP TEMPERATURE SENSOR
5
ADC OFFSET REGISTERS CONVERSION RATE REGISTER CONFIGURATION REGISTERS
D+ 10 NC 11 NC 12
NC = NO CONNECT
GND
Figure 1. Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.326.8703 (c) 2004 Analog Devices, Inc. All rights reserved.
04937-0-001
ADM1033 TABLE OF CONTENTS
General Description ......................................................................... 3 Specifications..................................................................................... 4 Absolute Maximum Ratings............................................................ 6 Thermal Characteristics .............................................................. 6 ESD Caution.................................................................................. 6 Pin Configuration and Function Descriptions............................. 7 Typical Performance Characteristics ............................................. 8 Functional Description .................................................................. 10 Internal Registers........................................................................ 10 Serial Bus Interface..................................................................... 10 LOCATION Input ...................................................................... 10 SMBus 2.0 ARP-Capable Mode ................................................ 10 SMBus 2.0 Fixed-and-Discoverable Mode.............................. 12 SMBus 2.0 Read and Write Operations ................................... 12 Register Addresses for Single/Block Byte Modes ................... 14 Write Operations ........................................................................ 14 Read Operations ......................................................................... 15 SMBus Timeout .......................................................................... 15 Packet Error Checking (PEC) ................................................... 15 Alert Response Address (ARA) ................................................ 15 Temperature Measurement System.............................................. 16 Internal Temperature Measurement ........................................ 16 Remote Temperature Measurement......................................... 16 Additional Functions ................................................................. 18 Layout Considerations ................................................................... 19 Limits, Status Registers, and Interrupts ....................................... 20 8-Bit Limits.................................................................................. 20 Out-of-Limit Comparisons ....................................................... 20 Analog Monitoring Cycle Time................................................ 20 Status Registers ........................................................................... 20 ALERT Interrupt Behavior........................................................ 21 Handling SMBusALERT Interrupts......................................... 22 Interrupt Masking Register ....................................................... 22 FAN_FAULT Output ................................................................. 23 Fault Queue ................................................................................. 23 Conversion Rate Register .......................................................... 23 THERM I/O Timer and Limits ................................................ 23 THERM % Limit Register ......................................................... 24 Fan Drive Signal ......................................................................... 25 Synchronous Speed Control ..................................................... 25 Fan Inputs.................................................................................... 26 Fan Speed Measurement ........................................................... 26 Fan Speed Measurement Registers........................................... 27 Reading Fan Speed ..................................................................... 27 Calculating Fan Speed ............................................................... 27 Alarm Speed................................................................................ 27 Look-Up Table: Modes of Operation....................................... 28 Look-Up Table ............................................................................ 28 Setting Up the Look-Up Table in Linear Mode...................... 29 Selecting which Temperature Channel Controls a Fan......... 29 Look-Up Table Hysteresis ......................................................... 29 Programming the THERM Limit for Temperature Channels ....................................................................................................... 30 XOR Tree Test Mode.................................................................. 30 Lock Bit........................................................................................ 30 SW Reset...................................................................................... 30 Outline Dimensions ....................................................................... 39 Ordering Guide .......................................................................... 39
REVISION HISTORY
8/04--Revision 0: Initial Version
Rev. 0 | Page 2 of 40
ADM1033 GENERAL DESCRIPTION
The ADM1033 is a remote and local temperature sensor and fan controller. Its remote channel accurately monitors the temperature of a remote thermal diode, which can be a discrete 2N3904/6 or located on a microprocessor die. The device can monitor its own ambient temperature as well. The ADM1033 is also used to monitor and control the speed of a cooling fan. The user can program a target fan speed, or use the look-up table to input a temperature-to-fan speed profile. The look-up table can be configured to run the fan at discrete speeds (discrete mode) or to ramp the fan speed with temperature (linear mode). The ADM1033 communicates over a 2-wire SMBus 2.0 interface. An 8-level LOCATION input allows the user to choose between SMBus 1.1 and SMBus 2.0. The ALERT output indicates error conditions. In addition, the
THERM I/O signals overtemperature as an output and times
THERM assertions as an input. Pin 8 can be configured as a reference input for the THERM (PROCHOT) input.
Rev. 0 | Page 3 of 40
ADM1033 SPECIFICATIONS
TA = TMIN to TMAX, VCC = VMIN to VMAX, unless otherwise noted.1 Table 1.
Parameter POWER SUPPLY Supply Voltage, VCC2 Supply Current, ICC Undervoltage Lockout Threshold Power-On Reset Threshold TEMPERATURE-TO-DIGITAL CONVERTER Internal Sensor Accuracy Resolution External Diode Sensor Accuracy -3 Resolution Remote Sensor Source Current 0.03125 85 34 5 1000 1 11 32 43 Min 3.0 Typ 3.3 Max 3.6 3 900 2.4 1 -4 0.03125 0.5 1 +2 2 +2 1 Units V mA A V V C C C C C C C A %/V ms ms ms Test Conditions/Comments
Interface inactive, ADC active Standby mode
2.5 1
20C TA 60C -40C TA +100C -40C TD +100C; TA = +40C -40C TD +100C; +20C TA +60C -40C TD +100C; -40C TA +100C High level Mid level Low level
Series Resistance Cancellation Power Supply Sensitivity Conversion Time (Local Temperature) Conversion Time (Remote Temperature) Total Conversion Time OPEN-DRAIN DIGITAL OUTPUTS (ALERT, THERM, FAN_FAULT DRIVE) Output Low Voltage, VOL High Level Output Leakage Current, IOH DIGITAL INPUT LEAKAGE CURRENT (TACH) Input High Current, IIH Input Low Current, IIL Input Capacitance, CIN DIGITAL INPUT LOGIC LEVELS (TACH) Input High Voltage, VIH Input Low Voltage, VIL Hysteresis OPEN-DRAIN SERIAL DATA BUS OUTPUT (SDA) Output Low Voltage, VOL High Level Output Leakage Current, IOH SERIAL BUS DIGITAL INPUTS (SCL, SDA) Input High Voltage, VIH Input Low Voltage, VIL Hysteresis ANALOG INPUTS (LOCATION, REF) Input Resistance
Averaging enabled Averaging enabled Averaging enabled
0.1 -1
0.4 1
V A A A pF V V mV p-p
IOUT = -6.0 mA; VCC = +3 V VOUT = VCC; VCC = 3 V VIN = VCC VIN = 0
1 7 2.0 -0.3 500 5.5 +0.8
0.1 2.1
0.4 1
V A V V mV k
IOUT = -6.0 mA; VCC = +3 V VOUT = VCC
0.8 500 80 125 160
Rev. 0 | Page 4 of 40
ADM1033
Parameter TACHOMETER ACCURACY Fan Speed Measurement Accuracy AGTL + INPUT (THERM) Input High Level Input Low Level SERIAL BUS TIMING3 Clock Frequency, fSCLK Glitch Immunity, tSW Bus Free Time, tBUF Start Setup Time, tSU:STA Start Hold Time, tHD:STA Stop Condition Setup Time, tSU:STO SCL Low Time, tLOW SCL High Time, tHIGH SCL, SDA Rise Time, tr SCL, SDA Fall Time, tf Data Setup Time, tSU:DAT Detect Clock Low Timeout, tTIMEOUT Min Typ Max 4 0.75 x REF 0.4 400 50 1.3 0.6 0.6 0.6 1.3 0.6 1000 300 100 25 35 Units % V V See Figure 2 kHz ns s s s s s s ns ns ns ms Test Conditions/Comments
See Note 4
1
Typicals are at TA = 25C and represent most likely parametric norm. Standby current typ is measured with VCC = 3.3 V. Timing specifications are tested at logic levels of VIL = 0.8 V for a falling edge and VIH = 2.1 V for a rising edge. Operation at 5.5 V is guaranteed by design, not production tested. 3 Guaranteed by design, not production tested. 4 SMBus timeout disabled by default. See the SMBus Timeout section for more information.
2
tLOW
SCL
tR
tF
tHD:STA
tHD:STA
SDA
tHD:DAT
tHIGH tSU:DAT
tSU:STA
tSU:STO
tBUF
P S S P
Figure 2. Serial Bus Timing Diagram
Rev. 0 | Page 5 of 40
04937-0-003
ADM1033 ABSOLUTE MAXIMUM RATINGS
Table 2.
Parameter Positive Supply Voltage (VCC) Voltage on Any Input or Output Pin except FAN_FAULT and LOCATION Voltage on FAN_FAULT1 Voltage on LOCATION Input Current at Any Pin Maximum Junction Temperature (TJmax) Storage Temperature Range Lead Temperature, Soldering (10 sec) IR Reflow Peak Temperature ESD Rating--All Pins Value -0.3 V to +6.5 V -0.3 V to +6.5 V VCC VCC + 0.3V 20 mA 150C -65C to +150C 300C 220C 1500 V
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
THERMAL CHARACTERISTICS
16-Lead QSOP Package: JA = 150C/W, JC = 39C/W
1
During power-up, the voltage on FAN_FAULT should not be higher than VCC.
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulates on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality.
Rev. 0 | Page 6 of 40
ADM1033 PIN CONFIGURATION AND FUNCTION DESCRIPTIONS
DRIVE TACH ALERT Comp NC GND VCC THERM FAN_FAULT/REF
1 2 3 4 5 6 7 8 16 15
SCL SDA SMBusALERT LOCATION NC NC D+
04937-0-002
ADM1033
TOP VIEW (Not to Scale)
14 13 12 11 10 9
D-
NC = NO CONNECT
Figure 3. Pin Configuration
Table 3. Pin Function Descriptions
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Mnemonic DRIVE TACH ALERT Comp NC GND VCC THERM FAN_FAULT/REF D- D+ NC NC LOCATION SMBusALERT SDA SCL Description DRIVE Pin Drives the Fan. Open-drain output. Requires a pull-up resistor. Fan Speed Measurement Input. Connects to the fan's TACH output to measure the fan speed. Open-Drain Active Low Output. Asserts low whenever a measurement goes outside its programmed limits, if not masked. Automatically goes high again when the measured parameter falls back within its limits. No Connect. Ground for Analog and Digital Circuitry. Power. Can be powered by 3.3 V standby power, if monitoring in low power states is required. Can be configured as an overtemperature interrupt output, or as an input to monitor PROCHOT output of an INTEL CPU. A timer measures assertion times on the THERM pin (either input or output). FAN_FAULT: Open-Drain Output. Asserts low whenever the fan stalls. REF: Analog Input Reference for THERM input. Cathode Connection for the Thermal Diode or Diode-Connected Transistor. Anode Connection for the Thermal Diode or Diode-Connected Transistor. No Connect. No Connect. 8-Level Analog Input. Used to determine the correct SMBus version and the SMBus address (in fixed-anddiscoverable mode), and to set the LLL bits in the UDID (in ARP-capable mode). Open-Drain Output. Alerts the system in the case of out-of-limit events such as overtemperature. Can be reset only with software. Serial Bus Bidirectional Data. Connects to the SMBus master's data line. Requires a pull-up resistor, if one is not provided elsewhere in the system. Serial SMBus Clock Input. Connects to the SMBus master's clock line. Requires a pull-up resistor, if one is not provided elsewhere in the system.
Rev. 0 | Page 7 of 40
ADM1033 TYPICAL PERFORMANCE CHARACTERISTICS
40
20 EXT 100mV p-p EXT 250mV p-p 15
D+ TO GND D+ TO VCC
20
TEMPERATURE ERROR (C)
0
TEMPERATURE ERROR (C)
10
-20 -40 -60
5
0
-80 -100 0 10 20 30 40 50 60 70 LEAKAGE RESISTANCE (M) 80 90
04937-0-004
-10 0 1M 2M 3M 4M 5M
100
6M
Figure 4. Temperature Error vs. PCB Track Resistance, DXP to GND and VCC
Figure 7. Remote Temperature Error vs. Power Supply Noise Frequency
0 -10
TEMPERATURE ERROR (C)
50 45
DEV 33 (C)
TEMPERATURE ERROR (C)
40 35 30 25 100mV 20 15 10 20mV 50mV 5 00 0 1M 2M 3M 4M NOISE FREQUENCY (Hz) 5M
04937-0-008
-20 -30 -40
DEV 31 (C) -50 -60 -70 -80 0 2 4 6 8 CAPACITANCE (nF) 10
04937-0-005
DEV 32 (C)
12
6M
Figure 5. Remote Temperature Error vs. D+, D- Capacitance
Figure 8. Remote Temperature Error vs. Common-Mode Noise Frequency Coupled on D+ and D-
100 90 DEV 33 80
TEMPERATURE ERROR (C) TEMPERATURE ERROR (C)
4.0 3.5 3.0 2.5 2.0 20mV 1.5 1.0 0.5 0 0 1M 2M 3M 4M NOISE FREQUENCY 5M
04937-0-009
70 60 50 40 30 20 DEV 32 0 -10 1 2 3 4 5 SERIES RESISTANCE IN D+/D- LINES (k) 6
04937-0-006
DEV 31
10
10mV
6M
Figure 6. Remote Temperature Error vs. Series Resistance on D+ and D-
Figure 9. Remote Temperature Error vs. Differential-Mode Noise Frequency Coupled on D+ and D-
Rev. 0 | Page 8 of 40
04937-0-007
-5
ADM1033
2 1 HIGH 4 SIGMA
TEMPERATURE ERROR (C)
0.7
0.6
STANDBY SUPPLY CURRENT
0 -1 -2 -3 MEAN -4 -5 -6 -7 -60 S1 S2 S3 S4 S5 -40 -20 V1 V2 V3 V4 V5 0 20 40 60 80 DIODE TEMPERATURE (C)
0.5
0.4 0.3 0.2
LOW 4 SIGMA 100 120
04937-0-010
0 0 1 2 3 4 SUPPLY VOLTAGE (V) 5 6
140
Figure 10. Remote Temperature Error vs. Actual Diode Temperature
Figure 13. Standby Supply Current vs. Supply Voltage
2 1 HIGH 4 SIGMA 0 -1
ERROR (C)
1200
1000
800
ICC (A)
-2 -3 MEAN -4 -5 -6 -7 -50 S1 S2 S3 S4 S5 0 V1 V2 V3 V4 V5 50 TEMPERATURE (C)
600 DEV 31 400 DEV 33 DEV 32
04937-0-014
LOW 4 SIGMA 100
04937-0-011
200
150
0 0.01
0.1
1 10 CONVERSION RATE (Hz)
100
Figure 11. Local Temperature Error vs. Actual Temperature
Figure 14. Supply Current vs. Conversion Rate
430
1.55
420 DEV 31 410
SUPPLY CURRENT
1.50
1.45
ICC (A)
400 DEV 33 390 380 DEV 32
04937-0-012
1.40
1.35
360 1 10 FSCL (kHz) 100
1000
1.25 -60
-40
-20
0 20 40 TEMPERATURE (C)
60
80
100
Figure 12. Standby Supply Current vs. SCLK Frequency
Figure 15. Supply Current vs. ADM1033 Temperature
Rev. 0 | Page 9 of 40
04937-0-015
370
1.30
04937-0-013
0.1
ADM1033 FUNCTIONAL DESCRIPTION
The ADM1033 is a local and remote temperature monitor and fan controller used in a variety of applications, including microprocessor-based systems. The device accurately monitors remote and ambient temperature and uses that information to quietly control the speed of a cooling fan. Whenever the fan stalls, the device asserts a FAN_FAULT output. The ADM1033 has a THERM I/O. As an input, this measures assertions on the THERM pin. As an output, it asserts a low signal to indicate when the measured temperature exceeds the programmed THERM temperature limits. The ADM1033 communicates over an SMBus 2.0 interface. Its LOCATION input determines which version of SMBus to use, as well as the SMBus address (in fixed-and-discoverable mode), and the LOCATION bits in the UDID (in ARP-capable mode).
VCC
ADM1033
R1 PIN 13 R2 GND LOCATION
04937-0-016
Figure 16. Bootstrapping the LOCATION Input
SMBus 2.0 ARP-CAPABLE MODE
In ARP-capable mode, the ADM1033 supports such features as address resolution protocol (ARP) and unique device identifier (UDID). The UDID is a 128-bit message that describes the ADM1033's capabilities to the master. The UDID also includes a vendor-specific ID for functionally equivalent devices.
VCC ARP LOCATION = 111 ARP LOCATION = 110 ARP LOCATION = 101 ARP LOCATION = 100 FD ADDRESS = 53h FD ADDRESS = 52h FD ADDRESS = 51h FD ADDRESS = 50h GND
INTERNAL REGISTERS
Table 4 gives a brief description of the ADM1033's principal internal registers. For more detailed information on the function of each register, refer to .
ADM1033 NO. 1
1.5k
ADM1033 NO. 2
1k
ADM1033 NO. 3
1k
ADM1033 NO. 4
1k
SERIAL BUS INTERFACE
The ADM1033 communicates with the master via the 2-wire SMBus 2.0 interface. It supports two SMBus 2.0 versions, determined by the value of the LOCATION input resistors. The first version is fully ARP-capable. This means that it supports address resolution protocol (ARP), allowing the master to dynamically address the device on power-up. It responds to ARP commands such as "Prepare to ARP." The second SMBus version, fixed-and-discoverable, is backward-compatible with SMBus 1.0 and 1.1. In this mode, the ADM1033 powers up with a fixed address, which is determined by the state of the LOCATION pin on power-up. Note: when using the ADM1033, addresses 0xC2 and 0xCA should not be used by any other device on the bus.
ADM1033 NO. 5
1k
ADM1033 NO. 6
1k
ADM1033 NO. 7
1.5k
ADM1033 NO. 8
Figure 17. Setting Up Multiple ADM1033 Addresses
LOCATION INPUT
The LOCATION input is a resistor divider input. It has multiple functions and can specify the following: the SMBus version (in fixed-and-discoverable or ARP-capable modes); the SMBus address (in fixed-and-discoverable mode); and the LLL bits (in UDID in ARP-capable mode). The voltage of this 8-level input is set by a potential divider. The voltage on LOCATION is sampled on power-up and digitized by the on-chip ADC to determine the LOCATION input value. Because the LOCATION input is sampled only at power-up, changes made while power is applied have no effect.
In SMBus 2.0 mode, this vendor-specific ID is generated by an on-chip random number generator. This should enable two adjacent ADM1033s in the same system to power-up with a different vendor-specific ID, allowing the master to identify the two separate ADM1033s and assign a different address to each. The state of the LOCATION input on power-up is also reflected in the UDID. This is useful when there are more than one ADM1033 in the system, so the master knows which one it is communicating with. The UDID values are listed in Table 6. The SMBus 2.0 master issues both general and directed ARP commands. A general command is directed at all ARP devices. A directed command is targeted at a single device, once an address has been established. The PEC byte must be used for ARP commands (refer to Packet Error Checking (PEC)). The ADM1033 responds to the following commands: * * * * Prepare to ARP (general) Reset device (general and directed) Get UDID (general and directed) Assign address (general)
Rev. 0 | Page 10 of 40
04937-0-017
ADM1033
Table 4. Internal Register Descriptions
Register Configuration Conversion Rate Address Pointer Status Interrupt Mask Value and Limit Offset Description Provides control and configuration of various functions on the device. Determines the number of measurements per second completed by the ADM1033. Contains the address that selects one of the other internal registers. When writing to the ADM1033, the first byte of data is always a register address, which is written to the address pointer register. Provides the status of each limit comparison. Allows the option to mask ALERTs due to particular out-of-limit conditions. Stores the results of temperature and fan speed measurements, along with their limit values. Allows the local and remote temperature channel readings to be offset by a twos complement value written to them. These values are automatically added to the temperature values (or subtracted from them if negative). This allows the systems designer to optimize the system, if required, by adding or subtracting up to 15.875C from a temperature reading. Contains the temperature value at which THERM is asserted and determines the level of hysteresis. Used to program the look-up table for the fan-speed-to-temperature profile. Reflects the state of the THERM input and monitors the duration of the assertion time of the signal as a percentage of a time window. The user can program the length of the time window.
THERM Limit and Hysteresis Look-Up Table THERM % Ontime and THERM % Limit
Table 5. Resistor Ratios for Setting LOCATION Bits
Ideal Ratio R2/(R1 + R2) N/A 0.8125 0.6875 0.5625 0.4375 0.3125 0.1875 N/A R1 (k) 0 18 22 12 15 47 82 O/C R2 (k) O/C 82 47 15 12 22 18 0 Actual R2/(R1 + R2) 1 0.82 0.6812 0.5556 0.4444 0.3188 0.18 0 Error (%) 0 +0.75 -0.63 -0.69 +0.69 +0.63 -0.75 0 SMBus Mode ARP1 ARP1 ARP1 ARP1 FD1 FD1 FD1 FD1 SMBus Address N/A N/A N/A N/A 0x53 0x52 0x51 0x50 UDID LLL 111 110 101 100 N/A N/A N/A N/A
1
FD denotes fixed-and-discoverable mode, ARP denotes ARP-capable mode.
Table 6. UDID Values
Bit No. <127:120> <1119:112> <111:96> <95:80> <79:64> <63:48> <47:32> <31:0> Name Device Capabilities Version/Revision: Vendor ID Device ID Interface Subsystem Vendor ID Subsystem Device ID Vendor-Specific ID Function Describes the ADM1033's capabilities (for instance, that it supports PEC and uses a random number address device) UDID version number (Version 1) and silicon revision identification Vendor ID number, assigned by the SBS Implementer's Forum or the PCI SIG Device ID Identifies the protocol layer interfaces supported by the ADM1033. This represents SMBus 2.0 as the Interface version. Subsystem Vendor ID = 0 (subsystem fields are unsupported) Subsystem Device ID = 0 (subsystem fields are unsupported) A unique number per device. Contains the LOCATION Information (LLL) and a 16-bit random number (x). See Table 5 for information on setting the LLL bits. Value 11000001 00001010 00010001 11010100 00010000 00110011 00000000 00000100 00000000 00000000 00000000 00000000 00000000 00000LLL xxxxxxxx xxxxxxxx
Rev. 0 | Page 11 of 40
ADM1033
SMBus 2.0 FIXED-AND-DISCOVERABLE MODE
The ADM1033 supports fixed-and-discoverable mode, which is backward-compatible with SMBus 1.0 and 1.1. Fixed-anddiscoverable mode supports all the same functionality as ARPcapable mode, except for assign address--in which case it powers up with a fixed address and is not changed by the assign address call. The fixed address is determined by the state of the LOCATION pin on power-up. It is not possible to mix read and write in one operation, because the type of operation is determined at the beginning and cannot be changed without starting a new operation. To write data to one of the device data registers or read data from it, the address pointer register (APR) must be set so that the correct data register is addressed. The first byte of a write operation always contains an address that is stored in the APR. If data is to be written to the device, the write operation contains a second data byte. The second data byte is written to the register selected by the APR. As shown in Figure 18, the device address is sent over the bus, followed by R/W set to 0. This is followed by two data bytes. The first data byte is the address of the designated internal data register, which is stored in the APR. The second data byte is the data to be written to the internal data register. When reading data from a register there are two possibilities: * If the ADM1033's APR value is unknown or incorrect, it must be set to the correct value before data can be read from the desired data register. To do this, perform a write to the ADM1033 as before; but this time send only the data byte containing the register. (See Figure 19.) A read operation is then performed. With the serial bus address and the R/W bit set to 1, the data byte is read from the data register. (See Figure 20.) If the APR is known to be already at the desired address, data can be read from the corresponding data register without first writing to the APR. In this case, Figure 19 can be omitted.
SMBus 2.0 READ AND WRITE OPERATIONS
The master initiates a data transfer by establishing a start condition, defined as a high-to-low transition on the serial data line (SDA) while the serial clock line (SCL) remains high. This indicates that an address/data stream is to follow. All slave peripherals connected to the serial bus respond to the start condition and shift in the next eight bits, which consist of a 7bit address (MSB first) plus an R/W bit. The last bit determines the direction of the data transfer (whether data is written to or read from the slave device). 1. The peripheral that corresponds to the transmitted address responds by pulling the data line low during the low period before the 9th clock pulse. This pulse is known as the acknowledge bit. All other devices on the bus remain idle while the selected device waits for data to be read from or written to it. If the R/W bit is a 0, the master writes to the slave device. If the R/W bit is a 1, the master reads from it. Data is sent over the serial bus in sequences of nine clock pulses--eight bits of data followed by an acknowledge bit from the slave device. Transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, as a low-to-high transition when the clock is high might be interpreted as a stop signal. The number of data bytes that can be transmitted over the serial bus in a single read or write operation is limited only by what the master and slave devices can handle. When all data bytes have been read or written, stop conditions are established. In write mode, the master pulls the data line high during the tenth clock pulse to assert a stop condition. In read mode, the master device overrides the acknowledge bit by pulling the data line high during the low period before the ninth clock pulse. This is known as no acknowledge. The master takes the data line low during the low period before the tenth clock pulse, then high during the tenth clock pulse to assert a stop condition.
2.
*
In Figure 18 to Figure 20, the serial bus address is determined by the state of the LOCATION pin on power-up.
3.
Rev. 0 | Page 12 of 40
ADM1033
1 SCL 9 1 9
SDA START BY MASTER
A6
A5
A4
A3
A2
A1
A0
R/W ACK. BY ADM1033
D7
D6
D5
D4
D3
D2
D1
D0 ACK. BY ADM1033
FRAME 1 SERIAL BUS ADDRESS BYTE 1 SCL (CONTINUED)
FRAME 2 ADDRESS POINTER REGISTER BYTE 9
SDA (CONTINUED)
D7
D6
D5
D4
D3
D2
D1
D0
04937-0-021
ACK. BY ADM1033 FRAME 3 DATA BYTE
STOP BY MASTER
Figure 18. Writing a Register Address to the Address Pointer Register, then Writing Data to the Selected Register
1
9
1
9
SCL
SDA
A6
A5
A4
A3
A2
A1
A0
R/W
D7
D6
D5
D4
D3
D2
D1
D0
04937-0-022
04937-0-023
START BY MASTER
FRAME 1 SERIAL BUS ADDRESS BYTE
ACK. BY ADM1033
FRAME 2 ADDRESS POINTER REGISTER BYTE
ACK. BY ADM1033
STOP BY MASTER
Figure 19. Writing to the Address Pointer Register Only (Send Byte)
1 SCL
9
1
9
SDA START BY MASTER
A6
A5
A4
A3
A2
A1
A0
R/W ACK. BY ADM1033
D7
D6
D5
D4
D3
D2
D1
D0 NO ACK. BY STOP BY ADM1033 MASTER
FRAME 1 SERIAL BUS ADDRESS BYTE
FRAME 2 DATA BYTE FROM ADM1033
Figure 20. Reading Data from a Previously Selected Register
Rev. 0 | Page 13 of 40
ADM1033
REGISTER ADDRESSES FOR SINGLE/BLOCK BYTE MODES
The ADM1033 supports single-byte and multiple-byte (block) read and write operations. The register address determines whether a single-byte or block operation is run. For a singlebyte operation, the MSB of the register address is set to 0; for a multiple-byte operation, it is set to 1. The number of bytes read from the ADM1033 in a multiple-byte operation is set in the #Bytes/Block Read Register at Address 0x00. The number of bytes written to it is specified in the block-write operation. The addresses quoted in the register map and throughout this data sheet assume single-byte operation. For multiple-byte operations, set the MSB of each register address to 1. The SMBus specifications define protocols for different types of read and write operations. The ADM1033 supports the following SMBus write protocols: send byte, write byte, block write, receive byte, and block read. The following abbreviations are used in the diagrams: S--START P--STOP R--READ W--WRITE A--ACKNOWLEDGE A--NO ACKNOWLEDGE Write Byte In this operation, the master device sends the register address and one data byte to the slave device as follows: 1. 2. 3. 4. The master asserts a start condition on SDA. The master sends the 7-bit slave address followed by a write bit (low). The addressed slave device asserts ACK on SDA. The master sends the register address. The MSB of the command code should equal 0 for a write-byte operation. If the MSB equals 1, a block-write operation takes place. The slave asserts ACK on SDA. The master sends a data byte. The slave asserts ACK on SDA. The master asserts a stop condition on SDA to end the transaction.
S SLAVE REG WA A ADDRESS ADDRESS
DATA
AP
04937-0-019
5. 6. 7. 8.
Figure 22. Write Byte
Block Write In this operation, the master device writes a block of data to a slave address as follows. A maximum number of 32 bytes can be written. 1. The master asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by a write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends the register address. This register address sets up the address pointer register and determines if a block write (MSB = 1) or a byte write (MSB = 0) takes place. 5. The slave asserts ACK on SDA. 6. The master sends the byte count. 7. The slave asserts ACK on SDA. 8. The master sends N data bytes. 9. The slave asserts ACK on SDA after each byte. 10. The master asserts a stop condition on SDA to end the transaction.
S SLAVE WA ADDRESS
WRITE OPERATIONS
Send Byte In this operation, the master device sends a single-command byte to a slave device as follows: 1. The master device asserts a start condition on SDA. 2. The master sends a 7-bit address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends the register address. 5. The slave asserts ACK on SDA. 6. The master asserts a stop condition on SDA, and the transaction ends.
S SLAVE REG WA AP ADDRESS ADDRESS
04937-0-018
The ADM1033 uses the send-byte operation to write a register address to the APR for a subsequent read from the same address. This is illustrated in Figure 21. The user may be required to read data from the register immediately after setting up the address. If so, the master can assert a repeat start condition immediately after the final ACK and carry out a single-byte read without asserting an intermediate stop condition.
REGISTER ADDRESS
A
BYTE A DATA 1 A DATA 2 A DATA N A P COUNT
Figure 23. Block Write
Rev. 0 | Page 14 of 40
04918-0-020
Figure 21. Send Byte
ADM1033
READ OPERATIONS
Receive Byte This operation is useful when repeatedly reading a single register. The register address must be set up prior to this, with the MSB at 0 to read a single byte. In this operation, the master device receives a single byte from a slave device as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the read bit (high). 3. The addressed slave device asserts ACK on SDA. 4. The master receives a data byte. 5. The master sends NO ACK on SDA. 6. The master asserts a stop condition on SDA and the transaction ends. In the ADM1033, the receive-byte protocol is used to read a single byte from a register whose address has previously been set by a send-byte or write-byte operation.
S SLAVE RA ADDRESS DATA AP
04937-0-024
S
SLAVE WA ADDRESS
REGISTER ADDRESS
AS
BYTE SLAVE RA A DATA 1 A DATA N A P COUNT ADDRESS
Figure 25. Block Read from RAM
SMBus TIMEOUT
The ADM1033 has a programmable SMBus timeout feature. When this is enabled, the SMBus typically times out after 25 ms of no activity. The timeout is disabled by default. It prevents SMBus hangups by releasing the bus after a period of inactivity. To enable the SDA timeout, set the SDA timeout bit (Bit 5) of Configuration Register 1 (Address 0x01) to 1. To enable the SCL timeout, set the SCL timeout bit (Bit 4) of Configuration Register 1 (Address 0x01) to 1.
PACKET ERROR CHECKING (PEC)
The ADM1033 supports packet error checking (PEC). This optional feature is triggered by the extra clock for the PEC byte. The PEC byte is calculated using CRC-8. The frame check sequence (FCS) conforms to CRC-8 by the following:
C( x ) = x 8 + x 2 + x + 1
For more information, consult www.SMBus.org.
Figure 24. Receive Byte
ALERT RESPONSE ADDRESS (ARA)
S ALERT RESPONSE DEVICE RA AP ADDRESS ADDRESS
04937-0-043
Block Read In this operation, the master reads a block of data from a slave device. The number of bytes to be read must be set in advance. To do this, use a write-byte operation to the #Bytes/Block Read Register at Address 0x00. The register address determines whether a block-read or a read-byte operation is to be completed (set MSB to 1 to specify a block-read operation). A maximum number of 32 bytes can be read. 1. The master asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends the register address (MSB = 1). 5. The slave asserts ACK on SDA. 6. The master asserts a repeated start on SDA. 7. The master sends the 7-bit slave address followed by the read bit (high). 8. The slave asserts ACK on SDA. 9. The slave sends the byte count. 10. The master asserts ACK on SDA. 11. The slave sends N data bytes. 12. The master asserts ACK on SDA after each data byte. 13. The master does not acknowledge after the Nth data byte. 14. The master asserts a stop condition on SDA to end the transaction.
Figure 26. Alert Response Address
When multiple devices exist on the same bus, the alert response address (ARA) feature allows an interrupting device to identify itself to the host. The ALERT output can be used as an interrupt output or as an SMBALERT. One or more ALERT outputs can be connected to a common SMBALERT line, which is connected to the master. If a device's ALERT line goes low, the following procedure occurs: 1. SMBALERT is pulled low. 2. The master initiates a receive-byte operation and sends the alert response address (ARA 0001 100). This is a general call address that must not be used as a specific device address. 3. The device with the low ALERT output responds to the ARA, and the master reads its device address. Once the address is known, it can be interrogated in the usual way. 4. If low ALERToutput is detected in more than one device, the one with the lowest device address has priority, in accordance with normal SMBus arbitration. 5. Once the ADM1033 has responded to the ARA, it resets its ALERT output. If the error persists, the ALERT is reasserted on the next monitoring cycle.
Rev. 0 | Page 15 of 40
04918-0-025
ADM1033 TEMPERATURE MEASUREMENT SYSTEM
INTERNAL TEMPERATURE MEASUREMENT
The ADM1033 contains an on-chip band gap temperature sensor. The on-chip ADC performs conversions on the sensor's output and outputs the temperature data in 13-bit format. The resolution of the local temperature sensor is 0.03125C. Table 7 shows the format of the temperature data MSBs. Table 8 shows the local and remote sensor extended resolution data for the LSBs. To ensure accurate readings, the LSBs should be read first. This locks the current LSBs and MSBs until the MSBs are read. They then start to update again. (Reading only the MSBs does not lock the registers.) Temperature updates to the look-up table take place in parallel, so fan speeds can be updated even if the MSBs are locked. Table 7. Temperature Data Format for Local and Remote Temperature High Bytes
Temperature (C) -64 -40 -32 -2 -1 0 1 2 10 20 50 75 100 125 150 191 Digital Output 0000 0000 0001 1000 0010 0000 0011 1110 0011 1111 0100 0000 0100 0001 0100 0010 0100 1010 0101 0100 0111 0010 1000 1011 1010 0100 1011 1101 1101 0110 1111 1111
Table 8. Local and Remote Sensor Extended Resolution
Extended Resolution (C) 0.0000 0.03125 0.0625 0.125 0.250 0.375 0.500 0.625 0.750 0.875 Temperature Low Bits 00000 00001 00010 00100 01000 01100 10000 10100 11000 11100
Temperature (C) = (MSB - 64C) + (LSB x 0.03125) Example: MSB = 0101 0100 = 84d LSB = 11100 = 14 Temperature C = (84 - 64) + (28 x 0.03125) = 20.875
REMOTE TEMPERATURE MEASUREMENT
The ADM1033 measures the temperature of one external diode sensor or diode-connected transistor, which is connected to Pins 9 and 10. These pins are dedicated temperature input channels. The series resistance cancellation (SRC) feature can automatically cancel out the effect of up to 1 k of resistance in series with the remote thermal diode. The forward voltage of a diode or diode-connected transistor, operated at a constant current, exhibits a negative temperature coefficient of about -2 mV/C. Unfortunately, the absolute value of VBE varies from device to device, and individual calibration is required to null this out. Therefore, the technique is unsuitable for mass production.
ADM1033
D+ 2N3906 D- 2N3904
ADM1033
D+
04937-0-026
D-
Figure 27. Measuring Temperature Using Discrete Transistors
Rev. 0 | Page 16 of 40
ADM1033
VDD
I
N2 x I
N1 x I
IBIAS
D+ REMOTE SENSING TRANSISTOR
VOUT+ TO ADC
04937-0-027
D-
LOW-PASS FILTER fC = 65kHz
VOUT-
Figure 28. ADM1033 Signal Conditioning
The ADM1033 operates at three different currents to measure the change in VBE. Figure 28 shows the input signal conditioning used to measure the output of an external temperature sensor. It also shows the external sensor as a substrate transistor, provided for temperature monitoring on some microprocessors. The external sensor works equally well as a discrete transistor. If a discrete transistor is used, the collector is not grounded and should be linked to the base. If a PNP transistor is used, the base is connected to the D- input and the emitter to the D+ input. If an NPN transistor is used, the emitter is connected to the D- input and the base to the D+ input. If the sensor is used in a very noisy environment, a capacitor value of up to 1000 pF can be placed between the D+ and D- inputs to filter the noise. However, additional parasitic capacitance on the lines between D+, D-, and the thermal diode should also be considered. The total capacitance should never be greater than 1000 pF. To measure each VBE, the sensor is switched between operating currents of I, (N1 x I), and (N2 x I). The resulting waveform is passed through a 65 kHz low-pass filter to remove noise, then to a chopper-stabilized amplifier that amplifies and rectifies the waveform. This produces a dc voltage proportional to VBE. These measurements are used to determine the temperature of the thermal diode, while automatically compensating for any series resistance on the D+ and/or D- lines. The temperature is stored in two registers as a 13-bit word.
To further reduce the effects of noise, digital filtering is performed by averaging the results of 16 measurement cycles at conversion rates of less than 16 Hz. An external temperature measurement takes nominally 32 ms when averaging is enabled and 6 ms when averaging is disabled. One LSB of the ADC corresponds to 0.03125C. The ADM1033 can theoretically measure temperatures from -64C to +191.96875C, although -64C and +191C are outside its operating range. The extended temperature resolution data format is shown in Table 8. The extended temperature resolution for the local and remote channels is stored in the extended temperature resolution registers (Reg. 0x40 = Local, Reg. 0x42 = Remote). Table 9. Temperature Measurement Registers
Register 0x40 0x41 0x42 0x43 Description Local Temperature, LSBs Local Temperature, MSBs Remote Temperature, LSBs Remote Temperature, MSBs Default 0x00 0x00 0x00 0x00
High and low temperature limit registers are associated with each temperature measurement channel. The appropriate status bit is set when the high and low limits are exceeded. Exceeding either limit can cause an SMBALERT interrupt. Table 10. Temperature Measurement Limit Registers
Register 0x0B 0x0C 0x0D 0x0E 0x0F 0x10 Description Local High Limit Local Low Limit Local THERM Limit Remote High Limit Remote Low Limit Remote THERM Limit Default 0x8B (75C) 0x54 (20C) 0x95 (85C) 0x8B (75C) 0x54 (20C) 0x95 (85C)
Rev. 0 | Page 17 of 40
ADM1033
ADDITIONAL FUNCTIONS
Several other temperature measurement functions available on the ADM1033 offer the systems designer added flexibility.
Removing Temperature Errors
As CPUs run faster and faster, it becomes more difficult to avoid high frequency clocks when routing the D+ and D- traces around a system board. Even when recommended layout guidelines are followed, temperature errors attributed to noise coupled onto the D+ and D- lines remain. High frequency noise generally gives temperature measurements that are too high by a constant amount. The ADM1033 has local and remote temperature offset registers at Addresses 0x16 and 0x17--one for each channel. By completing a one-time calibration, the user can determine the offset caused by the system board noise and remove it using the offset registers. The registers automatically add a twos complement word to the remote temperature measurements, ensuring correct readings in the value registers. Table 12. Offset Registers
Registration 0x16 0x17 Description Local Offset Remote Offset Default 0x00 0x00
Turn-Off Averaging
The ADM1033 performs averaging at conversion rates of less than or equal to eight conversions per second. This means that the value in the measurement register is the average of 16 measurements. For faster measurements, set the conversion rate to 16 conversions per second or greater. (Averaging is not carried out at these conversion rates.) Or, to switch off averaging at the slower conversion rates, set Bit 1 (AVG) of Configuration 1 Register (Address 0x01).
Single-Channel ADC Conversions
In normal operating mode, the ADM1033 converts on both the local temperature and remote channels. However, the user can set the ADM1033 to convert on one channel only. To enable single-channel mode, set the round robin bit (Bit 7) in Configuration Register 2 (Address 0x02) to 0. When the round robin bit equals 1, the ADM1033 converts on both temperature channels. In single-channel mode, it converts on one channel only, to be determined by the state of the channel selector bit (Bit 4) of Configuration Register 2 (Address 0x02). Table 11. Channel Selector
Bit 4 0 1 Channel Selector (Configuration 2) Local Channel (default) Remote Channel
Table 13. Offset Register Values
Code 0 0000 000 0 0000 001 0 0000 111 0 0001 111 0 0111 111 0 1111 111 1 0000 000 1 1111 000 Offset Value 0C (Default) 0.125C 0.875C 1.875C 7.875C 15.875C -16C -0.875C
Rev. 0 | Page 18 of 40
ADM1033 LAYOUT CONSIDERATIONS
Digital boards can be electrically noisy environments. Be sure to protect the analog inputs from noise, particularly when measuring the very small voltages from a remote diode sensor. Take the following precautions: * Place the ADM1033 as close as possible to the remote sensing diode. A distance of 4 inches to 8 inches is adequate, provided that the worst noise sources such as clock generators, data/address buses, and CRTs are avoided. Route the D+ and D- tracks close together, in parallel, with grounded guard tracks on each side. Provide a ground plane under the tracks if possible. Use wide tracks to minimize inductance and reduce noise pickup. A minimum of 5 mil track width and spacing is recommended. Try to minimize the number of copper/solder joints, which can cause thermocouple effects. Where copper/ solder joints are used, make sure that they are in both the D+ and D- path and at the same temperature. Thermocouple effects should not be a major problem because 1C corresponds to about 200 V, and thermocouple voltages are about 3 V/C of temperature difference. Unless there are two thermocouples with a big temperature differential between them, thermocouple voltages should be much less than 200 V.
GND 5MIL 5MIL D+ 5MIL 5MIL
D-
*
If the distance to the remote sensor is more than 8 inches, twisted pair cable is recommended. This works up to about 6 feet to 12 feet. For very long distances (up to 100 feet), use shielded twisted pair such as Belden #8451 microphone cable. Connect the twisted pair to D+ and D- and the shield to GND, close to the ADM1033. Leave the remote end of the shield unconnected to avoid ground loops.
*
*
*
Because the measurement technique uses switched current sources, excessive cable and/or filter capacitance can affect the measurement. When using long cables, the filter capacitor C1 may be reduced or removed. In any case, the total shunt capacitance should never exceed 1000 pF.
Noise Filtering
For temperature sensors operating in noisy environments, common practice is to place a capacitor across the D+ and D- pins to help combat the effects of noise. However, large capacitances affect the accuracy of the temperature measurement, leading to a recommended maximum capacitor value of 1000 pF. While this capacitor reduces the noise, it does not eliminate it, making it difficult to use the sensor in a very noisy environment. The ADM1033 has a major advantage over other devices when it comes to eliminating the effects of noise on the external sensor. The series resistance cancellation feature allows a filter to be constructed between the external temperature sensor and the part. The effect of any filter resistance seen in series with the remote sensor is automatically cancelled from the temperature result. The construction of a filter allows the ADM1033 and the remote temperature sensor to operate in noisy environments. Figure 30 shows a low-pass R-C-R filter with the following values: R = 100 and C = 1 nF. This filtering reduces both common-mode noise and differential noise.
100 D+ 1nF 100 D-
04110-0-009
*
5MIL
04937-0-028
5MIL GND 5MIL
Figure 29. Arrangement of Signal Tracks
*
Place a 0.1 F bypass capacitor close to the ADM1033.
REMOTE TEMPERATURE SENSOR
Figure 30. Filter Between Remote Sensor and ADM1033
Rev. 0 | Page 19 of 40
ADM1033 LIMITS, STATUS REGISTERS, AND INTERRUPTS
High and low limits are associated with each measurement channel on the ADM1033 and form the basis of system status monitoring. The user can set a status bit for any out-of-limit condition and detect it by polling the device. Alternatively, SMBusALERTs can be generated to flag a processor or microcontroller of an out-of-limit condition. The ADC performs round-robin conversions and takes 11 ms for the local temperature measurement and 32 ms for each remote temperature measurement with averaging enabled. The total monitoring cycle time for the average temperatures is, therefore, nominally 32 + 11 = 43 ms Once the conversion time elapses, the round robin starts again. For more information, refer to the Conversion Rate Register section. Fan TACH measurements take place in parallel and are not synchronized with the temperature measurements.
8-BIT LIMITS
Table 14 and Table 15 list all the 8-bit limits on the ADM1033: Table 14. Temperature Limit Registers
Register 0x0B 0x0C 0x0D 0x0E 0x0F 0x10 Description Local High Limit Local Low Limit Local THERM Limit Remote High Limit Remote Low Limit Remote THERM Limit Default 0x8B (75C) 0x54 (20C) 0x95 (85C) 0x8B (75C) 0x54 (20C) 0x95 (85C)
STATUS REGISTERS
The results of limit comparisons are stored in the status registers. A 1 represents an out-of-limit measurement; a 0 represents an in-limit measurement. The status registers are located at Addresses 0x4F to 0x51. If the measurement is outside its limits, the corresponding status register bit is set to 1. It remains set at 1 until the measurement falls back within its limits and either the status register is read or an ARA is completed. To poll the state of the various measurements, read the status registers over the serial bus. If Bit 0 (ALERT low) of Status Register 3 (Address 0x51) is set, this means the ADM1033 has pulled the ALERT output low. Pin 14 is an SMBusALERT output. This pin automatically notifies the system supervisor of an out-of-limit condition. Reading the status register clears the status bit, as long as the error condition has been cleared. Pin 3 is an ALERT Comp output. This pin asserts low when ever an unmasked measurement goes outside its limit. Unlike SMBusALERT, it automatically resets once the measurement falls back within the programmed limits. Status register bits are sticky. Whenever a status bit is set due to an out-of-limit condition, it remains set--even after the triggering event has cleared. The only way to clear the status bit is to read the status register (after the triggering event has cleared). Interrupt mask registers (Reg. 0x08, Reg. 0x09, Reg. 0x0A) allow individual interrupt sources to be masked from causing an ALERT. If one of these masked interrupt sources goes out of limit, its associated status bit is set in the status register.
Table 15. THERM Limit Register
Register 0x19 Description THERM % Limit Default 0xFF
OUT-OF-LIMIT COMPARISONS
The ADM1033 measures all parameters in a round-robin format and sets the appropriate status bit for out-of limit conditions. Comparisons are made differently, depending on whether the measured value is compared to a high or low limit. High Limit: Comparison Performed Low Limit: < Comparison Performed
ANALOG MONITORING CYCLE TIME
The analog monitoring cycle time begins on power-up or, if monitoring has been disabled, by writing a 1 to the monitor/ STBY bit of Configuration Register 1 (Address 0x01). The ADC measures each one of the analog inputs in turn; as each measurement is completed, the result is automatically stored in the appropriate value register. The round-robin monitoring cycle continues, unless it is disabled. To disable the cycle, write a 0 to the monitor/STBY bit (Bit 0) of Configuration Register 1 (Address 0x01).
Rev. 0 | Page 20 of 40
ADM1033
Table 16. Status Register 1 (Reg. 0x4F)
Bit No. 7 6 5 4 3 2 1 0 Name LH LL RH RL RD Unused Unused Unused Description 1 = Local high temperature limit has been exceeded. 1 = Local low temperature limit has been exceeded. 1= Remote high temperature limit has been exceeded. 1 = Remote low temperature limit has been exceeded. 1 = Remote diode error; indicates an open or short on the D1+/D1- pins. Reserved. Reserved. Reserved.
ALERT INTERRUPT BEHAVIOR
The ADM1033 generates an ALERT to signal out-of-limit conditions. Out-of-limit conditions can also be detected by polling the status registers. The ADM1033 has two ALERT outputs, called ALERT Comp and SMBusALERT. In SMBusALERT mode, the output remains low until the following combination of conditions occur: the measurement falls back within its programmed limits, and either the status register is read or an ARA is completed. In ALERT Comp mode, the output automatically resets once the temperature measurement falls back within the programmed limits. For the SMBusALERT output, a status bit is set when a measurement goes outside its programmed limit. If the corresponding mask bit is not set, the SMBusALERT output is pulled low. If the measured value falls back within the limits, the SMBusALERT output remains low until the corresponding status register is read or until an ARA is completed, as long as no other measurement is outside its limits. On the other hand, the ALERT Comp output is automatically pulled low when a measurement goes outside its programmed limits. Once the measurement falls back within its limits, the ALERT output is automatically pulled back high again, assuming no other measurement channel is outside its limits. The main difference between the two outputs is that the SMBusALERT does not reset without software intervention, while the ALERT Comp output automatically resets itself. Note: In this data sheet, an ALERT refers to both the ALERT Comp and SMBusALERT, unless otherwise stated.
TEMPERATURE LIMITS
Table 17. Status Register 2 (Reg. 0x50)
Bit No. 7 6 5 4 3 Name LT RT Unused T% TA Description 1 = Local THERM temperature limit has been exceeded. 1 = Remote THERM temperature limit has been exceeded. Reserved. 1 = THERM timer limit has been exceeded. 1 = One of the THERM limits has been exceeded; and the THERM output signal has been asserted. 1 = THERM pin is active. Clears on a read, if THERM is not active. Reserved. Reserved.
2 1 0
TS Res Res
Table 18. Status Register 3 (Reg. 0x51)
Bit No. 7 6 5 4 3 2 1 0 Name FS FA Res Res Res Res Res ALERT Description 1= Fan has stalled. 1= Fan ALARM speed, indicates fan is running at alarm speed. Reserved. Reserved. Reserved. Reserved. Reserved. 1= SMBusALERT low, indicates the ADM1033 has pulled the SMBusALERT line low.
ALERT, 70C
TIME SMBusALERT ALERT COMP CLEARED ON READ
04937-0-029
Figure 31. How ALERT Comparator and SMBusALERT Outputs Work
Rev. 0 | Page 21 of 40
ADM1033
HANDLING SMBUSALERT INTERRUPTS
To prevent tie-ups due to service interrupts, follow these steps: 1. Detect an SMBus assertion. 2. Enter the interrupt handler. 3. Read the status register to identify the interrupt source. 4. Mask the interrupt source by setting the appropriate mask bit in the interrupt mask registers (Reg. 0x08 to Reg. 0x0A). 5. Take the appropriate action for a given interrupt source. 6. Exit the interrupt handler. 7. Periodically poll the status register. If the interrupt status bit has cleared, reset the corresponding interrupt mask bit to 0. This causes the SMBusALERT output and status bits to behave as shown in Figure 32.
2 1 0 Res Res Res 6 5 4 3 LL RH RL RD
Table 19. Mask Register 1 (Reg. 0x08)
Bit No. 7 Name LH Description 1 masks the ALERT for the local high temperature. 1 masks the ALERT for the local low temperature. 1 masks the ALERT for the remote high temperature. 1 masks the ALERT for the remote low temperature. 1 masks the ALERT for the remote diode errors. Reserved. Reserved. Reserved.
Table 20. Mask Register 2 (Reg. 0x09)
Bit No. 7 6 5 4 Name Res Res Res T% TA Description Reserved. Reserved. Reserved. 1 masks the ALERT for the THERM timer limit. 1 masks the ALERT for the THERM limit being exceeded and the THERM output signal being asserted. 1 masks the ALERT for a transition on THERM; has no effect on ALERT in ALERT Comp mode. Reserved. Reserved.
HIGH LIMIT
TEMPERATURE CLEARED ON READ (TEMP BELOW LIMIT) "STICKY" STATUS BIT TEMP BACK IN LIMIT (STATUS BIT STAYS SET)
3
SMBusALERT
INTERRUPT MASK BIT SET INTERRUPT MASK BIT CLEARED (SMBusALERT REARMED)
04937-0-030
2
TS
Figure 32. Handling SMBusALERTs
1 0
Res Res
INTERRUPT MASKING REGISTER
Mask Registers 1, 2, and 3 are located at Addresses 0x08, 0x09, and 0x0A. These registers allow individual interrupt sources to be masked out to prevent the ALERT interrupts. Note that masking the interrupt source prevents only the ALERT from being asserted; the appropriate status bit is set as normal.
Table 21. Mask Register 3 (Reg. 0x0A)
Bit No. 7 6 5 4 3 2 1 0 Name FS FA Res Res Res Res Res Res Description 1 masks the ALERT for fan stalling. 1 masks the ALERT for fan running at ALARM speed. Reserved. Reserved. Reserved. Reserved. Reserved. Reserved.
Rev. 0 | Page 22 of 40
ADM1033
FAN_FAULT OUTPUT
The FAN_FAULT output signals when the fan stalls. Pin 8, a dual-function pin, defaults to a FAN_FAULT output. It can also be reconfigured as an analog input reference for the THERM input. To configure the pin, set the FAN_FAULT/REF bit (Bit 7) in Configuration Register 4 (Address 0x04) to 1.
CONVERSION RATE REGISTER
The ADM1033 makes up to 64 measurements per second. However, for the sake of reduced power consumption and better noise immunity, users can run the ADM1033 at a slower conversion rate. Averaging does not occur at rates of 16, 32, and 64 conversions per second. Table 23 lists the available rates. The conversion rate register is located at Address 0x05. Note that the current round-robin loop must be completed before the newly programmed conversion rate can take effect. Table 23. Conversion Rates
Code 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 0x08 0x09 0x0A 0x0B to 0xFF Conversion Rate 0.0625 0.125 0.25 0.5 1 2 4 8 16 32 64 Reserved
FAULT QUEUE
The ADM1033 has a programmable fault queue option that lets the user program the number of out-of-limit measurements allowable before generating an SMBusALERT. The fault queue affects only temperature measurement channels and is operational only in SMBusALERT mode. It performs some simple filtering, which is particularly useful at the higher conversion rates (16, 32, and 64 conversions per second), where averaging is not carried out. There is a queue for each of the temperature channels. If L (the value programmed to the fault queue) or more consecutive outof-limit measurements are made on the same temperature channel, the fault queue fills and the SMBusALERT output triggers. To fill the fault queue, the user needs L or more consecutive out-of-limit measurements on the local, or L or more consecutive out-of-limit measurements on the remote channel. The fault queue is independent of the state of the bits in the status register. Table 22. Fault Queue (Address 0x06)
Bits <3:0> 000x 001x 01xx 1xxx Fault Queue 1 2 3 4
THERM I/O TIMER AND LIMITS
Pin 7 can be configured as either an input or output. As an output, it is asserted low to signal that the measured temperature has exceeded preprogrammed temperature limits. The output is automatically pulled high again when the temperature falls below the (THERM - Hysteresis) limit. The value of hysteresis is programmable in Register 0x1A. THERM is enabled as an output by default on power-up.
TEMPERATURE LIMITS THERM, 85C THERM-HYST, 80C
To reset the fault queue, do one of the following: * * * SMBus ARA command Read Status Register 1 Power-on reset
The SMBusALERT clears, even if the condition that caused the SMBusALERT remains. The SMBusALERT is reasserted, if the fault queue fills up.
THERM
Figure 33. THERM Behavior
Rev. 0 | Page 23 of 40
04937-0-031
TIME
ADM1033
Once the THERM limits are exceeded, the fans are boosted to full speed--that is, as long as the boost disable bit (Bit 1) is not set in Configuration Register 2 (Address 0x02). To configure THERM as an input, set the THERM timer bit (Bit 2) of Configuration Register 1 (Address 0x01) to 1. (It no longer operates as an output.) The ADM1033 can then detect whenever the THERM input is asserted low. This can be connected to a trip point temperature sensor or to the PROCHOT output of a CPU. With processor core voltages reducing all the time, the threshold for the ADTL + PROCHOT output also reduces as new processors become available. The default threshold on THERM is the normal CMOS threshold. However, Pin 8 (FAN_FAULT/REF) can be reconfigured as a REF input. This is done by setting Bit 7 (FAN_FAULT/REF) in Configuration Register 4 (Address 0x04) to 1. The processor VCCP should be connected to this input to provide a reference for the THERM input. The resulting THERM threshold is 0.75 x VCCP, the correct threshold for an AGTL+ signal. The ADM1033 can also measure assertion times on the THERM input as a percentage of an on-time window. This window is programmable in Configuration Register 4 (Address 0x04) using Bits <6:4> (THERM % on-time window). Values of between 0.25 and 8 are programmable. The assertion time, as a percentage of the time window, is stored in the THERM % on-time register (Address 0x4E). A THERM % (0x19) limit is also associated with this register. Once the measured percentage exceeds the percentage limit, the THERM % exceeded bit (Bit 4) in Status Register 2 (Address 0x50) is asserted and an ALERT is generated, as long as the mask bit is not set. If the limit is set to 0x00, an ALERT is generated on the first assertion. If the limit is set to 0xFF, an ALERT is never generated. This is because 0xFF corresponds to the THERM input, which is asserted all the time. Table 24. THERM % On-Time Window
Code 000 001 010 011 100 101 110 111 THERM % On-Time Window 0.25 s 0.5 s 1s 2 4s 8s 8s 8s
When THERM is configured as an input only, set the enable THERM events bits in Configuration Register 4 (Address 0x04) to allow Pin 7 to operate as an I/O. To configure the THERM pin to be pulled low as an output whenever the local temperature exceeds the local THERM limit, set the enable local THERM events bit (Bit 0) of Configuration Register 4 (Address 0x04). To configure the THERM pin to be pulled low as an output whenever the remote temperature exceeds the remote THERM limit, set the enable remote THERM events bit (Bit 1) of Configuration Register 4 (Address 0x04).
THERM % LIMIT REGISTER
The THERM % limit is programmed to Register 0x19. An ALERT is generated if the THERM is asserted for longer than the programmed percentage limit. The limit is programmed as a percentage of the chosen time window. 0x00 = 0% 0xFF = 100% Therefore, 1 LSB = 0.39% Example If a time window of 8 seconds is chosen, and an ALERT is to be generated if THERM is asserted for more than 1 second, program the following value to the limit register: % Limit = 1/8 x 100 = 12.5% 12.5% / 0.39% = 32d = 0x20 = 0010 0000 An ALERT is generated if the THERM limit is exceeded after the time window has elapsed, assuming it is not masked.
Rev. 0 | Page 24 of 40
ADM1033
FAN DRIVE SIGNAL
The ADM1033 controls the speed of a cooling fan. Varying the duty cycle (on/off time) of a square wave applied to the fan varies the speed of the fan. The ADM1033 uses a control method called synchronous speed control, in which the PWM drive signal applied to the fan is synchronized with the fan's TACH signal. See the Synchronous Speed Control section. The external circuitry required to drive the fan is simple. A single N-channel MOSFET is the only drive device required. The specifications of the MOSFET depend on the maximum current required by the fan and the gate voltage drive (VGS < 3 V for direct interfacing to the drive pin). VGS can be greater than 3 V, as long as the pull-up on the gate is tied to 5 V. The MOSFET should also have a low on resistance to ensure that there is no significant voltage drop across the FET. A high on resistance reduces the voltage applied across the fan and, therefore, the maximum operating speed of the fan. Figure 34 shows a scheme for driving a 3-wire fan.
12V 10k 10k TACH 4.7k TACH 3.3V 100k DRIVE Q1 NDT3055L 12V
If in doubt as to whether a fan has an open collector or totempole TACH output, use one of the input signal conditioning circuits shown in the Fan Inputs section. When designing drive circuits with transistors and FETs, make sure that the drive pins are not required to source current and that they sink less than the maximum current specified.
SYNCHRONOUS SPEED CONTROL
The ADM1033 drives the fan using a control scheme called synchronous speed control. In this scheme, the PWM drive signal applied to the fan is synchronized with the TACH signal. Accurate and repeatable fan speed measurements are the main benefits. The fan is allowed to run reliably at speeds as low as 30 % of the full capability. The drive signal applied to the fan is synchronized with the TACH signal. The ADM1033 switches on the drive signal and waits for a transition on the TACH signal. When a transition takes place on the TACH signal, the PWM drive is switched off for a period of time called tOFF. The drive signal is then switched on again. The tOFF time is varied in order to vary the fan speed. If the fan runs too fast, the tOFF time is increased. If the fan runs too slow, the tOFF time is decreased. Because the drive signal is synchronized with the TACH signal, the frequency with which the fan is driven depends on the current speed of the fan and the number of poles in it. Figure 35 shows how the synchronous speed drive signal works. The ideal TACH signal is the signal that would be output from the fan, if power were applied 100% of the time. It is representative of the actual speed of the fan. The actual TACH signal is the signal seen on the TACH output from the fan, if using a scope. In effect, the actual TACH signal is the ideal TACH signal chopped with the drive signal.
12V FAN
1N4148
ADM1033
Figure 34. Interfacing a 3-Wire Fan to the ADM1033 Using an N-Channel MOSFET
Figure 34 uses a 10 k pull-up resistor for the TACH signal. This assumes that the TACH signal is an open collector from the fan. In all cases, the fan's TACH signal must be kept below 5 V maximum to prevent damaging the ADM1033.
POLE TRANSITION POINTS
IDEAL TACH
tPOLE
DRIVE
tOFF
ACTUAL TACH
04937-0-033
DASH = TACH FLOATS HIGH BY PULL-UP RESISTOR SOLID = TRUE TACH WHEN FAN IS POWERED
Figure 35. Drive Signal by Using Synchronous Control
04937-0-032
Rev. 0 | Page 25 of 40
ADM1033
FAN INPUTS
Pin 2 is the TACH input intended for fan speed measurement. This input is open-drain. Signal conditioning on the ADM1033 accommodates the slow rise and fall time of typical tachometer outputs. The maximum input signal range is from 0 V to 5 V, even when VCC is less than 5 V. If these inputs are supplied from fan outputs that exceed 0 V to 5 V, either resistive attenuation of the fan signal or diode clamping must be used to keep the fan inputs within an acceptable range. Figure 36 to Figure 38 show examples of possible fan input circuits.
5V OR 12V FAN VCC
The fan inputs have an input resistance of about 160 k to ground. Consider this when calculating resistor values. With a pull-up voltage of 12 V and pull-up resistor of less than 1 k, suitable values for R1 and R2 would be 100 k and 47 k. This gives a high input voltage of 3.83 V.
12V VCC
<1 k R1* TACH OUTPUT FAN(0-7) R2
ADM1033
FAN SPEED COUNTER
04937-0-037
*SEE TEXT
Figure 38. Fan with Strong TACH Pull-Up to Voltage > VCC to Totem Pole Output, Attenuated with R1/R2
PULL-UP 4.7k TYP
TACH OUTPUT VCC
ADM1033
TACH X ZD1* DRIVE X FAN SPEED COUNTER
FAN SPEED MEASUREMENT
The fan counter does not count the fan TACH output pulses directly. This is because the fan may be spinning at less than 1,000 rpm and it would take several seconds to accumulate a large and accurate count. Instead, the period of the fan revolution is measured by gating an on-chip 81.92 kHz oscillator into the input of a 16-bit counter for one complete revolution of the fan. Therefore, the accumulated count value is actually proportional to the fan tachometer period and inversely proportional to the fan speed. The number of poles in the fan must be programmed in Configuration Register 3 (Address 0x03). This number must be an even number only, because there cannot be an uneven number of poles in a fan. A TACH period is output for every two poles. Therefore, the number of poles must be known so that the ADM1033 can measure for a full revolution. Figure 39 shows the fan speed measurement period, assuming that the fan outputs an ideal TACH signal. In reality, the TACH signal output by the fan is chopped by the drive signal. However, because the drive signal and TACH signal are synchronized, there is enough information available for the ADM1033 to measure the fan speed accurately.
100k TYP
*CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 x VCC
Figure 36. Fan with TACH Pull-Up to Voltage > 5 V, Clamped with Zener Diode
If the fan output has a resistive pull-up to 12 V (or another voltage greater than 5 V), the fan output can be clamped with a Zener diode, as shown in Figure 36. Select a Zener voltage that is greater than VIH but less than 5 V, allowing for the voltage tolerance of the Zener. A value of between 3 V and 5 V is suitable.
12V VCC
TACH OUTPUT PULL-UP TYP <1 k OR TOTEM POLE R1 10k
ADM1033
FAN(0-7) ZD1 ZENER* FAN SPEED COUNTER
* CHOOSE ZD1 VOLTAGE APPROXIMATELY 0.8 x VCC
Figure 37. Fan with Strong TACH Pull-Up to Voltage > VCC or Totem Pole Output, Clamped with Zener and Resistor
04937-0-036
04937-0-035
CLOCK
Or, resistive attenuation can be used, as shown in Figure 38. R1 and R2 should be chosen such that 2 V < VPULL-UP x R2/(RPULL-UP + R1 + R2) < 5 V
Figure 39. Fan Speed Measurement for a 4-Pole Fan
Rev. 0 | Page 26 of 40
04937-0-038
If the fan has a strong pull-up (less than 1 k to 12 V) or a totem-pole output, then a series resistor can be added to limit the Zener current, as shown in Figure 37.
IDEAL TACH
FAN MEASUREMENT PERIOD
ADM1033
FAN SPEED MEASUREMENT REGISTERS
The16-bit measurements listed in Table 25 are stored in the TACH value registers. Table 25. TACH Value Registers
Register 0x4A 0x4B Description TACH Period, LSB TACH Period, MSB Default 0xFF 0xFF
ALARM SPEED
The fan ALARM speed (Bit 6) in Status Register 3 (Address 0x51) is set whenever the fan runs at alarm speed. This occurs if the device is programmed to run the fan at full speed whenever the THERM temperature limits are exceeded. The device runs at alarm speed, for example, if the Boost Disable bit (Bit 1) of the Configuration 2 Register (Address 0x02) is not set to 1.
Fan Response Register
READING FAN SPEED
Reading back the fan speed involves a 2-register read for each measurement. The low byte should be read first. This freezes the high byte until both high and low byte registers have been read, preventing erroneous fan speed measurement readings. The fan tachometer reading registers report back the number of 12.20 s period clocks (81.92 kHz oscillator) gated to the fan speed counter for one full rotation of the fan (assuming the correct number of poles is programmed). Because the ADM1033 essentially measures the fan TACH period, the higher the count value, the slower the fan's actual speed. A 16bit fan TACH reading of 0xFFFF indicates that the fan has stalled or is running very slowly (<75 rpm).
The ADM1033 fan speed controller operates by reading the current fan speed, comparing it with the programmed fan speed, and then updating the drive signal applied to the fan. The fan response register determines the rate at which the ADM1033 looks at and updates the drive signal. Different fans have different inertias and respond to a changing drive signal more or less quickly than others. The fan's response register allows the user to tailor the ADM1033 to a particular fan, to prevent situations like overshoot. The user selects the number of updates to the drive signal per second. Table 26 lists the available options. Table 26. Fan Response Codes
Code 000 001 010 011 100 101 110 111 Update Rate 1.25 updates/s 2.5 updates/s = default 5 updates/s 10 updates/s 20 updates/s 40 updates/s 80 updates/s 160 updates/s
CALCULATING FAN SPEED
Fan speed in rpm is calculated as follows. This calculation assumes the number of poles programmed in Configuration Register 3 (Address 0x03) is correct for the fan used. Fan Speed (rpm) = (81920 x 60)/Fan TACH Reading where the Fan TACH Reading is the 16-bit Fan Tachometer Reading. Example: TACH High Byte (Reg. 0x28) = 0x7 TACH Low Byte (Reg. 0x29) = 0xFF What is the fan speed in rpm? Fan TACH Reading = 0x17FF = 6143d rpm = (f x 60)/Fan TACH Reading rpm = (81920 x 60)/6143 Fan Speed = 800 rpm
Table 27. Fan Response Register (Address 0x3C)
Bit <7:3> <2:0> Function Unused Fan Response
Rev. 0 | Page 27 of 40
ADM1033
LOOK-UP TABLE: MODES OF OPERATION
The ADM1033 look-up table has two modes of operation used to determine the behavior of the system: * * Manual mode Look-up table
LOOK-UP TABLE
The ADM1033 allows the user to program a temperature-tofan-speed profile. There are 24 registers in the look-up table, eight for temperature and 16 for target fan speed (each target fan speed is two registers). In total, there are eight available points. There are two options when programming the look-up table. It can be programmed to make the fan run at discrete speeds and jump to the new speed once the temperature threshold is crossed. Or, it can linearly ramp the TACH count between the two temperature thresholds. Figure 40 and Figure 41 show what the look-up table looks like, if all eight points are used on the one curve for both fans. Figure 40 shows the transfer curve when the fan is programmed to run at discrete speeds. The ADM1033 spins the fan at its new speed once a threshold is crossed.
FAN SPEED
Manual Mode
In manual mode, the ADM1033 is under software control. The software programs the required fan speed value or target rpm value. The ADM1033 then outputs that fan speed. Programming Target Fan Speed In this mode, the user programs the target rpm as a TACH count for N poles or a TACH count for one full rotation of the fan. This assumes that the number of poles is programmed correctly in Configuration 3 Register (Address 0x03). Follow these steps to program the target fan speed: 1. 2. Place the ADM1033 in manual mode. Set Bit 7 (Table/SW) of Configuration Register 1 (Address 0x01) = 0. Program the target TACH count (fan speed) using the following equation: TACH Count = (f x 60)/R where: f = clock frequency = 81.92 kHz R = required rpm value Example 1: If the desired value is 5,000 rpm, program the following value to the TACH pulse period registers: TACH Pulse Period = (f x 60)/5000 TACH Pulse Period = 983d = 0x03D7 Example 2: If the desired value is 3,500 rpm, program the following value to the TACH pulse period registers: TACH Pulse Period = (f x 60)/3500 TACH Pulse Period = 1404d = 0x057C Table 28. Registers to be Programmed
Fan Example 1 Example 1 Example 2 Example 2 Description Look-Up Table LSB Look-Up Table MSB Look-Up Table LSB Look-Up Table MSB Address 0x2A 0x2B 0x2C 0x2D Value 0xD7 0x03 0x7C 0x05
TACH COUNT 8 TACH COUNT 7 TACH COUNT 6 TACH COUNT 5 TACH COUNT 4 TACH COUNT 3 TACH COUNT 2 TACH COUNT 1
04937-0-039 04937-0-040
T1
T2
T3
T4
T5
T6
T7
T8 TEMPERATURE
Figure 40. Programming the Look-Up Table in Discrete RPM Mode
Figure 41 shows the transfer curve if the linear fan speeds option is chosen. At temperature T1, the fan runs at Fan Speed 1. As the temperature increases, the fan speed increases until it reaches Fan Speed 2 at T2.
FAN SPEED TACH COUNT 8 TACH COUNT 7 TACH COUNT 6 TACH COUNT 5 TACH COUNT 4 TACH COUNT 3 TACH COUNT 2 TACH COUNT 1
T1
T2
T3
T4
T5
T6
T7
T8 TEMPERATURE
Figure 41. Programming the Look-Up Table in Linear Fan Speeds Mode
Rev. 0 | Page 28 of 40
ADM1033
FAN SPEED
SETTING UP THE LOOK-UP TABLE IN LINEAR MODE
When discrete/linear speed (Bit 2) is set to 1 (default), the TACH count decreases linearly and the fan speed increases with temperature. At temperature TX, the fan runs at FSX and speed increases with temperature to FSX+1 at temperature TX+1. Alternatively, the fan can be run at discrete fan speeds. When discrete/linear speed (Bit 2) is set to 0, the fan runs at a new speed once the temperature threshold is exceeded.
TACH COUNT 2 TO 8
TACH COUNT 1
04918-0-041
T1 TEMPERATURE
T2
T (3 TO 8) = 191 C
Figure 42. Programming Two Points on the Look-Up Table
SELECTING WHICH TEMPERATURE CHANNEL CONTROLS A FAN
Fan Behavior Register (Address 0x07) Bits <1:0> = DRIVE Behavior The ADM1033 can be configured so that either the local temperature or the remote temperature controls the fan. In default, the remote temperature controls the fan. Table 30. Drive BHVR Bits
Bits 00 01 10 11 Drive x BHVR Local Temperature Controls the Fan Remote Temperature Controls the Fan Remote Temperature Controls the Fan Fan Runs at Full Speed
Once the temperature exceeds the highest temperature point in the look-up table, the fan speed remains at the highest speed until the temperature drops below the T7 temperature value. If the temperatures in T1 to T8 are not programmed in succession, the fan speed moves to the next highest programmed temperature as the temperature increases. Similarly, when the temperature decreases, it ignores programmed higher temperatures and jumps to the next lower temperature. Therefore, the temperature-to-fan-speed profile for increasing and decreasing temperature can be different. When programming the look-up table, the user has the option to use between two and eight points for the fan (eight points only if the same curve is to be used for both fans). If the user wants to program only the transfer curve and knows the starting temperature, minimum fan speed, maximum temperature, and maximum fan speed, then only four parameters are required: T1, T2, FS1, and FS2. The remaining look-up temperature thresholds should remain at their default values of +191C. FS 3 to FS8 should be programmed with the same value as FS2 to give the flat curve, if required, or, they can be left at the default value of 0. However, it is normal to program a THERM limit as well. Once this temperature is exceeded and the boost bit is set, the fan runs to full speed. This overrides the table. Table 29. Look-Up Table Register Addresses
x 1 2 3 4 5 6 7 8 Temperature, x 0x22 0x23 0x24 0x25 0x26 0x27 0x28 0x29 RPMx, LSB 0x2A 0x2C 0x2E 0x30 0x32 0x34 0x36 0x38 RPMx, MSB 0x2B 0x2D 0x2F 0x31 0x33 0x35 0x37 0x39
LOOK-UP TABLE HYSTERESIS
The user can program a hysteresis to be applied to the look-up table. The advantage of this is apparent, if the temperature is cycling around one of the threshold temperatures, particularly when the look-up table is configured in discrete mode. It is not as important in linear mode. Table 31. Programming the Hysteresis
Code 0000 0000 0000 0001 0000 0010 0000 0101 0000 1000 0000 1111 Hysteresis Value 0C 1C 2C 5C 8C 15C
The hysteresis register of the look-up table is at Address 0x3A. A hysteresis value of between 0C and 15C can be programmed with a resolution of 1C and applied to all the temperature thresholds. Table 31 gives sample values for programming.
Rev. 0 | Page 29 of 40
ADM1033
PROGRAMMING THE THERM LIMIT FOR TEMPERATURE CHANNELS
THERM is the absolute maximum temperature allowed on a temperature channel. Above this temperature, a component such as the CPU or VRM might operate beyond its safe operating limit. When the temperature exceeds THERM, all fans are driven at full speed to provide critical system cooling. The fans remain running at 100% until the temperature drops below THERM - Hysteresis. The hysteresis value can be programmed; its default is 5C. If the boost disable bit (Bit 1) is set in Configuration Register 2, the fans do not run to full speed. The THERM limit is considered the maximum worst-case operating temperature of the system. Exceeding any THERM limit runs all fans at full speed, a condition with very negative acoustic effects. This limit should be set up as a fail-safe and not exceeded under normal system operating conditions. The THERM temperature limit registers are listed in Table 32. Table 32. THERM Hysteresis Registers
Address 0x0D 0x10 Description Local THERM Limit Remote THERM Limit Default 0x95 (85C) 0x95 (85C)
XOR TREE TEST MODE
The ADM1033 includes an XOR tree test mode. This mode is useful for in-circuit test equipment at board-level testing. By applying stimulus to the pins included in the XOR test, it is possible to detect opens or shorts on the system board. Figure 43 shows the signals exercised in this mode.
TACH1 ALERT_COMP
THERM
FAN_FAULT/REF
LOCATION
04937-0-042
ALERT
DRIVE1
Figure 43. XOR Tree Test
LOCK BIT
Setting the lock bit (Bit 6) of Configuration Register 1 (Address 0x01) makes all the lockable registers read-only. These registers remain read only until the ADM1033 is powered down and back up again. For more information on which registers are lockable, see Table 33.
The THERM hysteresis register is at Address 0x1A. A value is programmed and applied to both temperature channels--local and remote. A THERM hysteresis value of between 0C and 15C can be programmed with a resolution of 1C. See Table 33. Table 33. Programming THERM Hysteresis
Code 0000 0000 0000 0001 0000 0010 0000 0101 0000 1000 0000 1111 Hysteresis Value 0C 1C 2C 5C 8C 15C
SW RESET
Setting the software reset bit (Bit 0) of Configuration Register 1 (Address 0x01) resets all software-resettable bits to their default value. For more information on resetting registers and their default values, see Table 34 to Table 68.
Rev. 0 | Page 30 of 40
ADM1033
Table 34. ADM1033 Registers
Address 0x00/80 0x01/81 0x02/82 0x03/83 0x04/84 0x05/85 0x06/86 0x07/87 0x08/88 0x09/89 0x0A/8A 0x0B/8B 0x0C/8C 0x0D/8D 0x0E/8E 0x0F/8F 0x10/90 0x16/96 0x17/97 0x19/99 0x1A/9A 0x22/A2 0x23/A3 0x24/A4 0x25/A5 0x26/A6 0x27/A7 0x28/A8 0x29/A9 0x2A/AA 0x2B/AB 0x2C/AC 0x2D/AD 0x2E/AE 0x2F/AF 0x30/B0 0x31/B1 0x32/B2 0x33/B3 0x34/B4 0x35/B5 0x36/B6 0x37/B7 0x38/B8 0x39/B9 0x3A/BA 0x3C/BC 0x3D\BD 0x3E\BE R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R R Description #Bytes/Block Read Configuration 1 Configuration 2 Configuration 3 Configuration 4 Conversion Rate Fault Queue Fan Behavior Mask 1 Mask 2 Mask 3 Local High Limit Local Low Limit Local THERM Limit Remote High Limit Remote Low Limit Remote THERM Limit Local Offset Remote Offset THERM % Limit THERM Hysteresis Look-Up Table T1 Look-Up Table T2 Look-Up Table T3 Look-Up Table T4 Look-Up Table T5 Look-Up Table T6 Look-Up Table T7 Look-Up Table T8 Look-Up Table, FS1 Look-Up Table, FS1 Look-Up Table, FS2 Look-Up Table, FS2 Look-Up Table, FS3 Look-Up Table, FS3 Look-Up Table, FS4 Look-Up Table, FS4 Look-Up Table, FS5 Look-Up Table, FS5 Look-Up Table, FS6 Look-Up Table, FS6 Look-Up Table, FS7 Look-Up Table, FS7 Look-Up Table, FS8 Look-Up Table, FS8 Look-Up Table Hysteresis Fan Response Device ID Company ID Bit 7 7 Table/SW RR RES FF/REF RES RES RES LH RES FS 7 7 7 7 7 7 7 7 7 RES 7 7 7 7 7 7 7 7 7 15 7 15 7 15 7 15 7 15 7 15 7 15 7 15 RES RES 7 7 Bit 6 6 Lock RES RES %T RES F1 Off RES LL RES FA 6 6 6 6 6 6 6 6 6 RES 6 6 6 6 6 6 6 6 6 14 6 14 6 14 6 14 6 14 6 14 6 14 6 14 RES RES 6 6 Bit 5 5 SDA RES RES %T RES RES RES RH RES RES 5 5 5 5 5 5 5 5 5 RES 5 5 5 5 5 5 5 5 5 13 5 13 5 13 5 13 5 13 5 13 5 13 5 13 RES RES 5 5 Bit 4 4 SCL CS RES %T RES RES RES RL %T RES 4 4 4 4 4 4 4 4 4 RES 4 4 4 4 4 4 4 4 4 12 4 12 4 12 4 12 4 12 4 12 4 12 4 12 RES RES 4 4 Bit 3 3 ALERT LUT #FP XOR Conv FQ RES RD TA RES 3 3 3 3 3 3 3 3 3 Hys 3 3 3 3 3 3 3 3 3 11 3 11 3 11 3 11 3 11 3 11 3 11 3 11 HYS RES 3 3 Bit 2 2 TIMER D/L #FP RES Conv FQ RES RES TS RES 2 2 2 2 2 2 2 2 2 Hys 2 2 2 2 2 2 2 2 2 10 2 10 2 10 2 10 2 10 2 10 2 10 2 10 HYS FR 2 2 Bit 1 1 AVG BD #FP RTM Conv FQ DB RES RES RES 1 1 1 1 1 1 1 1 1 Hys 1 1 1 1 1 1 1 1 1 9 1 9 1 9 1 9 1 9 1 9 1 9 1 9 HYS FR 1 1 Bit 0 0 MON Reset #FP LTM Conv FQ DB RES RES RES 0 0 0 0 0 0 0 0 0 Hys 0 0 0 0 0 0 0 0 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 HYS FR 0 0
Default
0x20 0x01 0x84 0x44 0x00 0x07 0x01 0x09 0x52 0x10 0x00 0x8B 0x54 0x95 0x8B 0x54 0x95 0x00 0x00 0x00 0x05 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF
Lockable Y Y Y Y Y Y Y Y N N N N N Y N N Y Y Y Y N Y Y Y Y Y Y Y Y Y Y Y Y Y
0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0x00 0x00 0x33 0x41
Y Y Y Y Y Y Y Y Y Y Y Y Y N N
Rev. 0 | Page 31 of 40
ADM1033
Address 0x3F\BF 0x40\C0 0x41\C1 0x42\C2 0x43\C3 0x4A\CA 0x4B\CB 0x4E\CE 0x4F\CF 0x50\D0 0x51\D1 R/W R R R R R R R R R R R Description Revision Register Local Temperature Local Temperature Remote Temperature Remote Temperature TACH Period TACH Period THERM % On-Time Status 1 Status 2 Status 3 Bit 7 7 4 12 4 12 7 15 7 LH LT FS Bit 6 6 3 11 3 11 6 14 6 LL RT FA Bit 5 5 2 10 2 10 5 13 5 RH RES RES Bit 4 4 1 9 1 9 4 12 4 RL %T RES Bit 3 3 0 8 0 8 3 11 3 RTH TA RES Bit 2 2 RES 7 RES 7 2 10 2 RES TS RES Bit 1 1 RES 6 RES 6 1 9 1 RES RES RES Bit 0 0 RES 5 RES 5 0 8 0 RES RES ALERT
Default
Lockable
0x02 0x00 0x00 0x00 0x00 0xFF 0xFF 0x00 0x00 0x00 0x00
N N N N N N N N N N N
Table 35. Register 0x00, # Bytes/Block Read, Power-On Reset = 0x20, Lock = Y, S/W Reset = Y Bit Name R/W Description <7:0> # Bytes Block Read R/W Block reads are # bytes/block read long. The maximum is 32 bytes, the SMBus transaction limit.
Table 36. Register 0x01, Configuration Register 1, Power-On Default = 0x01, Lock = Y, SW Reset = Y
Bit 7 6 5 4 3 2 1 0 Name SW Con Lock Bit SDA Timeout SCL Timeout Reserved Enable THERM Timer Averaging Off Monitor/STBY R/W R/W R/W R/W R/W R/W R/W R/W R/W Description Set to 1 to have look-up table control the fan speed. Set to 0 to put ADM1033 in software/manual control mode. Default = 0. Set to 1 to prevent the user from writing to the ADM1033 registers. 1 = ADM1033 registers locked. 0 = ADM1033 registers unlocked. Default = 0. 1 = SDA timeout enabled. 0 = SDA timeout disabled. Default = 0. 1 = SCL timeout enabled. 0 = SDL timeout disabled. Default = 0. Reserved. 1 = timer enabled, 0 = timer disabled. Enables THERM as an input. Default = 0. Disables averaging at the slower conversion rates (8 Hz and slower). Averaging is automatically disabled at the higher (16, 32, and 64) conversion rates. Default = Averaging On = 0. Set to 1 to enable monitoring of temperature. Set to 0 to disable temperature monitoring. PowerOn Default = 1.
Table 37. Register 0x02, Configuration Register 2, Power-On Default = 0x84, Lock = Y, SW Reset = Y
Bit 7 <6:5> 4 3 2 1 0 Name Round Robin Reserved Channel Selector Reserved Discrete/Linear RPM Boost Disable SW Reset R/W R/W R/W R/W R/W R/W R/W R/W Description Enables round-robin mode. Set to 0 for single-channel mode. (The ADC converts on only one channel, which is determined by the channel selector bits.) Default = Round Robin = 1. Reserved. 0 = local temperature measurements, 1 = remote temperature measurements. Reserved. Determines whether the fans run at discrete speeds or whether the fan speed increases with temperature between the two thresholds. Default = 1 = linear. Set to 1 to prevent fans from being boosted, if either THERM temperature or THERM timer limits are exceeded. Under these conditions, the fans run at the previously calculated speed. Default = 0. Set this bit to 1 to reset the ADM1033 registers to their default values, excluding the limit registers, offset registers, and look-up table registers. This bit self-clears. Default = 0.
Table 38. Register 0x03, Configuration Register 3, Power-On Default = 0x44, Lock = Y, SW Reset = Y
Bit <7:4> <3:0> Name Unused #Poles Fan R/W R/W R/W Description Reserved. Write the number of poles in the fan to this register. Power-On Default = 4 poles = 100. This value should be an even number only.
Rev. 0 | Page 32 of 40
ADM1033
Table 39. Register 0x04, Configuration Register 4, Power-On Default = 0x00, Lock = Y, SW Reset = Y
Bit 7 <6:4> Name FAN_FAULT REF THERM % Time Window R/W R/W R/W Description Sets the function for Pin 8. 0 = Default = FAN_FAULT Output (THERM Input is CMOS). 1 = Reference Input for THERM . These bits set the time window over which THERM % is calculated. 000 = 0.25 s 001 = 0.5 s 010 = 1 s 011 = 2 s 100 = 4 s 101 = 8 s 110 = 8 s 111 = 8 s Set this bit to 1 to enable the XOR connectivity test. Reserved. This bit enables THERM assertions as an output. Functions when the THERM timer is enabled and the remote temperature exceeds its THERM limit. This bit enables THERM assertions as an output. Functions when the THERM timer is enabled and the local temperature exceeds its THERM limit.
3 2 1 0
XOR Test Unused Enable Remote THERM Events Enable Local THERM Events
R/W R/W R/W R/W
Table 40. Register 0x05, Conversion Rate Register, Power-On Default = 0x0A, Lock = Y, SW Reset = Y
Bit 7 <6:4> <3:0> Name Reserved Unused Conversion Rate R/W R/W R R/W Description Reserved. Do not write a 1 to this bit. Reserved. These 4 bits set the conversion rates of the ADM1033. Changing these bits does not update the conversion rate until the start of the next round robin. 0000 = 0.0625 conversions/s 0001 = 0.125 conversions/s 0010 = 0.25 conversions/s 0011 = 0.5 conversions/s 0100 = 1 conversion/s 0101 = 2 conversions/s 0110 = 4 conversions/s 0111 = 8 conversions/s 1000 = 16 conversions/s 1001 = 32 conversions/s 1010 = 64 conversions/s
Table 41. Register 0x06, Fault Queue, Power-On Default = 0x01, Lock = Y, SW Reset = Y
Bit <7:4> <3:0> Name Unused Fault Queue Length R/W R R/W Description Reserved. These 4 bits set the fault queue (the number of out-of-limit measurements made before an ALERT is generated). 000x = 1 001x = 2 01xx = 3 1xxx = 4
Rev. 0 | Page 33 of 40
ADM1033
Table 42. Register 0x07, Fan BHVR Register, Power-On Default = 0x09, Lock = Y, SW Reset = Y
Bit 7 6 <5:2> <1:0> Name Reserved Fan Off Reserved DRIVE BHVR R/W R R/W R R/W Description Reserved. When this bit is set to 1, the fan switches off, regardless of programmed target fan speed. Default = 0. Reserved. Determine which temperature source controls the DRIVE Output. 00 = local temp controls the DRIVE. 01 = remote temperature controls the DRIVE. 10 = remote temperature controls the DRIVE. 11 = DRIVE at full speed.
Table 43. Register 0x08, Mask Register 1, Power-On Default = 0x52, Lock = N, SW Reset = Y
Bit 7 6 5 4 3 2 1 0 Name Local Temp High Local Temp Low Remote High Remote Low Remote Diode Error Unused Unused Unused R/W R/W R/W R/W R R R R R Description A 1 disables the corresponding interrupt status bit from causing the interrupt output to be set. The status bit is not affected. Default = 0. A 1 disables the corresponding interrupt status bit from causing the interrupt output to be set. The status bit is not affected. Default = 1. A 1 disables the corresponding interrupt status bit from causing the interrupt output to be set. The status bit is not affected. Default = 0. A 1 disables the corresponding interrupt status bit from causing the interrupt output to be set. The status bit is not affected. Default = 1. A 1 disables the corresponding interrupt status bit from causing the interrupt output to be set. The status bit is not affected. Default = 0. Reserved. Reserved. Reserved.
Table 44. Register 0x09, Mask Register 2, Power-On Default = 0x10, Lock = N, SW Reset = Y
Bit <7:5> 4 3 2 Name Unused THERM % THERM Assert THERM_State R/W R R/W R/W R/W Description Unused. A 1 disables the corresponding interrupt status bit from setting the interrupt output. The status bit is not affected. Default = 0. A 1 disables the corresponding interrupt status bit from setting the interrupt output. The status bit is not affected. Default = 0. A 1 disables the corresponding interrupt status bit from setting the interrupt output. The status bit is not affected. Default = 0. This bit has no effect for the ALERT Comp output. Unused.
<1:0>
Unused
R
Table 45. Register 0x0A, Mask Register 3, Power-On Default = 0x00, Lock = N, SW Reset = Y
Bit 7 6 5 4 3 2 1 0 Name Fan Stalled Fan Alarm Speed Reserved Reserved Reserved Reserved Reserved Reserved R/W R/W R/W R R R R R R Description A 1 disables the corresponding interrupt status bit from setting the interrupt output. The status bit is not affected. Default = 0. A 1 disables the corresponding interrupt status bit from setting the interrupt output. The status bit is not affected. Default = 0. Reserved. Default = 0. Reserved. Default = 0. Reserved. Default = 0. Reserved. Default = 0. Reserved. Default = 0. Reserved. Default = 0.
Rev. 0 | Page 34 of 40
ADM1033
Table 46. Register 0x0B, Local High Limit, Power-On Default = 0x8B, Lock = N, SW Reset = N
Bit <7:0> Name Local High Limit R/W R/W Description When the local temperature exceeds this point, the corresponding interrupt status bit is set.
Table 47. Register 0x0C, Local Low Limit, Power-On Default = 0x54, Clock = N, SW Reset = N
Bit <7:0> Name Local Low Limit R/W R/W Description When the local temperature falls below this point, the corresponding interrupt status bit is set.
Table 48. Register 0x0D, Local THERM Limit, Power-On Default = 0x95, Lock = Y, SW Reset = N
Bit <7:0> Name Local THERM Limit R/W R/W Description When the local temperature exceeds this point, the corresponding status bit is set and the THERM output is activated.
Table 49. Register 0x0E, Remote High Limit, Power-On Default = 0x8B, Lock = N, SW Reset = N
Bit <7:0> Name Remote High Limit R/W R/W Description When the remote temperature exceeds this point, the corresponding interrupt status bit is set.
Table 50. Register 0x0F, Remote Low Limit, Power-On Default = 0x54, Lock = N, SW Reset = N
Bit <7:0> Name Remote Low Limit R/W R/W Description When the remote temperature falls below this point, the corresponding interrupt status bit is set.
Table 51. Register 0x10, Remote THERM Limit, Power-On Default = 0x95, Lock = Y, SW Reset = N
Bit <7:0> Name Remote THERM Limit R/W R/W Description When the temperature exceeds this point, the corresponding status bit is set and the THERM output is activated.
Table 52. Register 0x16, Local Offset Register, Power-On Default = 0x00, Lock = Y, SW Reset = N
Bit <7:0> Name Local Offset R/W R/W Description Allows a twos complement offset to be automatically added to or subtracted from the local temperature measurement. Resolution = 0.125C. Maximum offset = -16C to +15.875C. Default = 0.
Table 53. Register 0x17, Remote Offset Register, Power-On Default = 0x00, Lock = Y, SW Reset = N
Bit <7:0> Name Remote Offset R/W R/W Description Allows a twos complement offset to be automatically added to or subtracted from the remote temperature measurement. Resolution = 0.125C. Maximum offset = -16C to +15.875C. Default = 0.
Table 54. Register 0x19, THERM Timer % Limit, Power-On Default = 0xFF, Lock = Y, SW Reset = N
Bit <7:0> Name THERM Timer on % Limit R/W R/W Description If the THERM is asserted for greater than or equal to the THERM timer on % limit of the time window, then the corresponding status bit is set.
Rev. 0 | Page 35 of 40
ADM1033
Table 55. Register 0x1A, THERM Hysteresis, Power-On Default = 0x05, Lock = Y, SW Reset = N
Bit <7:4> <3:0> Name Reserved THERM Hysteresis R/W R R/W Description Reserved. An unsigned THERM hysteresis value, LSB = 1C. Once THERM has been activated on a temperature channel, if the temperature drops below the THERM limit - hysteresis, the THERM is deactivated.
Table 56. Look-Up Table Registers, Lock = Y, SW Reset = Y
Register Address 0x22 0x23 0x24 0x25 0x26 0x27 0x28 0x29 0x2A 0x2B 0x2C 0x2D 0x2E 0x2F 0x30 0x31 0x32 0x33 0x34 0x35 0x36 0x37 0x38 0x39 R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W Description Look-Up Table, T1 Look-Up Table, T2 Look-Up Table, T3 Look-Up Table, T4 Look-Up Table, T5 Look-Up Table, T6 Look-Up Table, T7 Look-Up Table, T8 Look-Up Table, RPM1, LSB Look-Up Table, RPM1, MSB Look-Up Table, RPM2, LSB Look-Up Table, RPM2, MSB Look-Up Table, RPM3, LSB Look-Up Table, RPM3, MSB Look-Up Table, RPM4, LSB Look-Up Table, RPM4, MSB Look-Up Table, RPM5, LSB Look-Up Table, RPM5, MSB Look-Up Table, RPM6, LSB Look-Up Table, RPM6, MSB Look-Up Table, RPM7, LSB Look-Up Table, RPM7, MSB Look-Up Table, RPM8, LSB Look-Up Table, RPM8, MSB Power-On Default 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF
Table 57. Register 0x3A, Look-Up Table Hysteresis, Power-On Default = 0x02, Lock = Y, SW Reset = Y
Bit <7:4> <3:0> Name Reserved Look-Up Table Hysteresis R/W R R/W Description Reserved. These bits determine the hysteresis applied to the temperature thresholds in the look-up table. LSB size = 1C.
Table 58. Register 0x3, Fan Response Register, Power-On Default = 0x11, Lock = Y, SW Reset = Y
Bit <7:3> <2:0> Name Reserved Fan Response R/W R R/W Description Reserved. These bits set the fan's response in the rpm control mode. 000 = 1.25 updates/s 001 = 2.5 updates/s (default) 010 = 5 updates/s 011 = 10 updates/s 100 = 20 updates/s 101 = 40 updates/s 110 = 80 updates/s 111 = 160 updates/s
Rev. 0 | Page 36 of 40
ADM1033
Table 59. Register 0x3D, Device ID, Power-On Default = 0x33, Lock = N, SW Reset = N
Bit <7:0> Name Device ID R/W R Description This read-only value contains the device ID, which is 0x33.
Table 60. Register 0x3E, Company ID, Power-On Default = 0x41, Lock = N, SW Reset = N
Bit <7:0> Name Company ID R/W R Description This read-only value contains the company ID, which is 0x41.
Table 61. Register 0x3D, Revision Register, Power-On Default = 0x02, Lock = N, SW Reset = N
Bit <7:0> Name Revision ID R/W R Description This read-only value contains the revision ID.
Table 62. Register 0x40/41, Local Temperature Registers, Power-On Default = 0x02, Lock = N, SW Reset = Y
Bit <4:0> <12:5> Name Local Temperature LSB Local Temperature MSB R/W R R Description Contains the LSBs of the last measured local temperature value. Resolution = 0.03125C. Contains the MSBs of the last measured local temperature value. Resolution = 1C.
Table 63. Register 0x42/43, Remote Temperature Registers, Power-On Default = 0x00, Lock = N, SW Reset = Y
Bit <4:0> <12:5> Name Remote Temperature LSB Remote Temperature MSB R/W R R Description Contains the LSBs of the last measured remote temperature value. Resolution = 0.03125C. Contains the MSBs of the last measured remote temperature value. Resolution = 1C.
Table 64. Register 0x4A/4B, TACH Period, Power-On Default = 0xFF, Lock = N, SW Reset = Y
Bit <7:0> <15:8> Name Fan Period Count, LSB Fan Period Count, MSB R/W R R Description This register contains the LSBs of the last measured fan revolution count. This register contains the MSBs of the last measured fan revolution count.
Table 65. Register 0x4E, THERM % On-Time; Power-On Default = 0x00, Lock = N, SW Reset = Y
Bit <7:0> Name THERM % On Time R/W R Description This value represents the % on time of THERM activity within the time window set by the configuration bits.
Table 66. Register 0x4F, Status 1, Power-On Default = 0x00, Lock = N, SW Reset = Y
Bit 7 6 5 4 3 <2:0> Name Local Temp High Local Temp Low Remote Temp High Remote Temp Low Remote Diode Error Reserved R/W R R R R R R Description A 1 indicates the local high limit has been tripped. A 1 indicates the local low limit has been tripped. A 1 indicates the remote high limit has been tripped. A 1 indicates the remote low limit has been tripped. A 1 indicates a short or an open has been detected on the remote temperature channel. This test is completed once on each conversion. Reserved.
Rev. 0 | Page 37 of 40
ADM1033
Table 67. Register 0x50, Status 2, Power-On Default = 0x00, Lock = N, SW Reset = Y
Bit 7 6 5 4 3 2 1 0 Name Local THERM Remote THERM Reserved THERM % Exceeded THERM Asserted THERM_State Reserved Reserved R/W R R R R R R R R Description A 1 indicates the local THERM limit has been tripped. A 1 indicates the remote THERM limit has been tripped. Reserved for future use. A 1 indicates the THERM signal has been asserted for longer than the programmed limit. Clear on read. If THERM % Limit = 0x00 and THERM is asserted, it reasserts immediately. A 1 indicates the THERM signal has been asserted low, as an input only. A 1 indicates the THERM pin has been asserted low as an output. Reserved. Reserved.
Table 68. Register 0x51, Status Register 3, Power-On Default = 0x00, Lock = N, SW Reset = Y
Bit 7 6 5 4 3 2 1 0 Name Fan Stalled Fan Alarm Speed Reserved Reserved Reserved Reserved Reserved ALERT Low R/W R R R R R R R R Description A 1 indicates the fan has stalled. A 1 indicates the fan is running at full speed, due to an ALARM condition (for instance, if the THERM temperature limit is exceeded). Reserved. Reserved. Reserved. Reserved. Reserved. A 1 indicates the ADM1033 has pulled the ALERT output pin low. Allows polling of a single status register to determine if an ALERT condition has occurred in any of the status registers.
Rev. 0 | Page 38 of 40
ADM1033 OUTLINE DIMENSIONS
0.193 BSC
16 9
0.154 BSC
1 8
0.236 BSC
PIN 1 0.065 0.049 0.069 0.053
0.010 0.025 0.004 BSC COPLANARITY 0.004
0.012 0.008
SEATING PLANE
0.010 0.006
8 0
0.050 0.016
COMPLIANT TO JEDEC STANDARDS MO-137AB
Figure 44. 16-Lead Shrink Small Outline Package [QSOP] (RQ-16) Dimensions shown in inches
ORDERING GUIDE
Model ADM1033ARQ ADM1033ARQ-REEL ADM1033ARQ-REEL7 ADM1033ARQZ1 ADM1033ARQZ-REEL1 ADM1033ARQZ-REEL71 Temperature Range -40C to +125C -40C to +125C -40C to +125C -40C to +125C -40C to +125C -40C to +125C Package Description 16-Lead QSOP 16-Lead QSOP 16-Lead QSOP 16-Lead QSOP 16-Lead QSOP 16-Lead QSOP Package Option RQ-16 RQ-16 RQ-16 RQ-16 RQ-16 RQ-16
1
Z = Pb-free part.
Rev. 0 | Page 39 of 40
ADM1033 NOTES
(c) 2004 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D04937-0-8/04(0)
Rev. 0 | Page 40 of 40